UL CE ETL Certificate UTP Cat6 Lan Cable

Shenzhen KW-LINK Electronic Co.,Ltd | Updated: Nov 10, 2016


UL CE ETL Certificate UTP Cat6 Lan Cable


Specialization: 

 

* Unshielded twisted pairs

* AWG: 24/26/28AWG  Optional

* Conductor: Stranding or Solid CCAM/CCA/CCU/CU/ Bare copper available

* Insulation: HD—PE

* Unrip rope: optional

* Jacket: PVC or LSNH

* Impedance: 100±15% O at 1 ~100MHz

* Reference Standard: YD/T1019-2001,ANSI/TIA/EIA-568B,ISO/IEC11801

* Print Legend: CM or CMR

 

* Specification: 4P

 

* Rated Temperature: -40°C ~ + 75°C

 

 

 Diameter of Cable

 

Conductor

Insulation

Core Number

Jacket

AWG

Specification

mm

Material

Thickness

(NOM.mm)

Material

Thickness

(NOM.mm)

 OD

(NOM.mm)




24

1/0.511

HD-PE

0.18

4P

PVC or LSNH

0.55

5.4


26

1/0.404

HD-PE

0.18

4P

PVC or LSNH

0.55

5.0


 

 

Scope Application:

 

Mainly used in the Building Correspondence Synthesis Wiring System the Work Area Correspondence Leading-out Terminal and between the Connection Distribution Frame Wiring, As Well As the Housing Synthesis Wiring System’s User Correspondence Leading-out Terminal Arrives at Place of Exile between Coils’ wiring.

 


       These simple features--the physical layout of the cable, the consistency of its dimensions, the rate and consistency of twist--cause a variety of effects upon high frequency signals run through the cable. To perform reliably and up-to-spec, network cabling needs to be able to meet some rather exacting specifications, which relate directly to just that: what happens to high-frequency signals run through it. High-speed data signals are not at all easy to convey reliably from point to point. If you've heard people say that it's very easy to do because, after all, it's digital, and "just ones and zeros," -- well -- that's one of those ideas which is intuitively very appealing and which turns out to be terribly wrong. To put it simply, the difficulty of actually getting those ones and zeros, at very high bitrates, through a cable and out the other end is surprisingly great, and sometimes for reasons which are far from obvious. In fact, contrary to common belief, it's not even really just ones and zeros--the different encoding schemes involve as many as sixteen distinct signal levels. There are, in fact, very good engineering reasons why data centers are generally not built using the cheapest available imported data cabling.