Products List
Contact Us

Add:No.110,Liguang New Industrial Zone,Guanlan Street,Longhua New District,Shenzhen

Contact:

Abbie Chow / Shadow Hsiung

Tel:

(0086)755-8379-9309

(0086)755-8297-1183

Fax:

(0086)755-8297-5415/888

Mob:

(0086)178-2039-5231

(0086)135-9029-8041

E-mail:015@kw-link.net

Web: www.cablekw.com

Our service hotline
(0086)755-8297-1183

Exhibition

Home > ExhibitionContent

Hotest Selling Network Cable UTP Cat6 Cable Ethernet Cable

Shenzhen KW-LINK Electronic Co.,Ltd | Updated: Nov 10, 2016


Hotest Selling Network Cable UTP Cat6 Cable Ethernet Cable


Specialization: 

 

* Unshielded twisted pairs

* AWG: 24/26/28AWG  Optional

* Conductor: Stranding or Solid CCAM/CCA/CCU/CU/ Bare copper available

* Insulation: HD—PE

* Unrip rope: optional

* Jacket: PVC or LSNH

* Impedance: 100±15% O at 1 ~100MHz

* Reference Standard: YD/T1019-2001,ANSI/TIA/EIA-568B,ISO/IEC11801

* Print Legend: CM or CMR

 

* Specification: 4P

 

* Rated Temperature: -40°C ~ + 75°C

 

 

 Diameter of Cable

 

Conductor

Insulation

Core Number

Jacket

AWG

Specification

mm

Material

Thickness

(NOM.mm)

Material

Thickness

(NOM.mm)

 OD

(NOM.mm)




24

1/0.511

HD-PE

0.18

4P

PVC or LSNH

0.55

5.4


26

1/0.404

HD-PE

0.18

4P

PVC or LSNH

0.55

5.0


 

 

Scope Application:

 

Mainly used in the Building Correspondence Synthesis Wiring System the Work Area Correspondence Leading-out Terminal and between the Connection Distribution Frame Wiring, As Well As the Housing Synthesis Wiring System’s User Correspondence Leading-out Terminal Arrives at Place of Exile between Coils’ wiring.



 

       The difference between Cat 5e, Cat 6, and Cat 6a cable is not so much in the basic design as it is in the tolerances. As the bitrate, and correspondingly the frequency, of the signal increases, smaller and smaller discontinuities and inconsistencies in the cable become relevant. Cat 5e is required to meet certain specs for signals up to 100 MHz (one "Hertz" is one complete wave, e.g., a sine wave, per second, and a "Megahertz" is one million of those per second). Cat6 is required to meet tighter specifications, and to meet those specs to 250 MHz. Cat6a must meet the same specifications as Cat 6, but must also meet similar specification limits all the way out to 500 MHz. So, while the basic cable architecture doesn't change between Categories, the demand for consistency and quality in manufacturing does; for example, a sloppy connectorization that's "just good enough" for a Cat 5e cable will almost certainly cause the cable to fail at Cat 6.